2.3 Electric Installation
This subsection describes how to connect
into your Local Area
2N
®
Helios IP Force
Network (LAN) and how to connect supply voltage and the electric lock.
PCB Connectors
Picture shows the lay-out of connectors on the
printed circuit
2N
®
Helios IP Force
board (PCB). Cables, accessories and other system components are connected to
connectors X1 through X22.
Connectors description:
X1 – Loudspeaker
X4 – Camera module
X5 – Button 1
SW1 – Reset button (555v3 version only)
X6 – Configuration jumpers
X8 – Extending module (RFID card reader or additional switch)
X10 – Buttons 1 through 4
X11 – LAN
X12 – Servicing connector
X13 – Keypad module
X15 – Left-hand microphone
X16 – Right-hand microphone
X17 – Relay NO and NC contact max. 30 V / 1 A AC/DC
X18 – Switched output 9 up to 13 V DC depending on power supply (PoE: 9 V;
adaptor: power supply voltage minus 1 V), max 700 mA
X19 – Power input 12 V ±15 % / 2 A DC
LED1/2 – System status indicators
LED3 – LAN connection activity indicator