Security relay, Function, Specifications – 2N Helios IP Force User Manual

Page 42: Installation, Connection

Advertising
background image

42

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Security Relay

The

(Part No. 9159010) is used for enhancing security between the

Security Relay

intercom and the connected electric lock. The

is

2N Helios IP Security Relay

®

designed for any

intercom model with firmware versions 1.15 and

2N Helios IP

®

higher. It significantly enhances security of the connected electric lock as it prevents
lock opening by forced intercom tampering.

Function:

The

is a device installed between an intercom (outside

2N Helios IP Security Relay

®

the secured area) and the electric lock (inside the secured area). The 2N Helios IP

®

includes a relay that can only be activated if the valid opening code is

Security Relay
r e c e i v e d

f r o m

t h e

i n t e r c o m . . R e f e r

t o

t h e

for details.

https://faq.2n.cz/pages/viewpage.action?pageId=30776808

Specifications:

Passive switch: NO and NC contacts, up to 30 V / 1 A AC/DC
Active switch output: 12 V / 700 mA DC
Dimensions: (56 Ч 31 Ч 24) mm
Weight: 20 g

Installation:

Install the

onto a two-wire cable between the intercom

2N Helios IP Security Relay

®

and the electric lock inside the area to be secured (typically behind the door). The
device is powered and controlled via this two-wire cable and so can be added to an
existing installation. Thanks to its compact dimensions, the device can be installed into
a standard mounting box.

Connection:

Connect the

to the intercom as follows:

2N Helios IP Security Relay

®

To the intercom active output (OUT1 or OUT2) , or
To the intercom relay output with a 12 V DC serial external power supply.

Connect the electric lock to the

output as follows:

2N Helios IP Security Relay

®

To the active 12 V / 700 mA DC output, or
To the relay output with a serial external power supply.

Advertising