Wiegand isolator, Status signalling, Configuration – 2N Helios IP Force User Manual

Page 43: Connection

Advertising
background image

43

2N TELEKOMUNIKACE a.s., www.2n.cz

®

The device also supports a Departure button connected between the ‘PB’ and ‘-
HeliosIP’ terminals. Press the Departure button to activate the output for 5 seconds.

Status signalling:

Green LED

Red LED

Status

blinking

off

Operational mode

on

off

Activated output

blinking

blinking

Programming mode – waiting for initialisation

on

blinking

Error - wrong code received

Configuration:

Connect the

to the properly set intercom switch

2N Helios IP Security Relay

®

output; refer to the

. Make sure that one

2N Helios IP Configuration Manual

®

LED at least on the

is on or blinking.

2N Helios IP Security Relay

®

Press and hold the

Reset button for 5 seconds to

2N Helios IP Security Relay

®

put the device in the programming mode (both the red and green LEDs are
blinking).
Activate the intercom switch using the keypad, telephone, etc. The first code sent
from the intercom will be stored in the memory and considered valid. After code
initialisation, the

will pass into the operational

2N Helios IP Security Relay

®

mode (the green LED is blinking).

Connection:

Wiegand Isolator

The

(Part No. 9159011) is usef for galvanic isolation of the

Wiegand Isolator

Wiegand bus.