4.

Description of Connectors, PCB Versions 535v5

Figure:

Terminal Block X2 Connection

Terminal block X2 includes 10 terminals whose functions are distinguished by colour.
Terminals 5–10 are used for connecting

to the

2N

®

Helios IP Vario

Ethernet. Terminals 3–4 are designed for connecting the electric lock and terminals 1–2
help connect an external 12 V / 2 A DC power supply if no PoE power supply is
available.

The terminal block is included in the package. To adjust an already installed 2N

®

, disconnect it IP from the power supply. Then pull to remove

Helios IP Vario
the terminal block from the printed circuit board.
Insert the wires under the respective terminals.
Tighten the terminals using a flat screwdriver.
Replace the terminal block to the printed circuit board.

Caution

Make sure that the cables leading through the 2N

®

Helios IP Vario

cover bottom groove are installed properly. For the correct installation of
the cables refer to Figure 2.7.