Terminal block x2 connection – 2N Helios IP Vario User Manual
Page 25
25
1.
2.
3.
4.
Description of Connectors, PCB Versions 535v5
Figure:
Terminal Block X2 Connection
Terminal block X2 includes 10 terminals whose functions are distinguished by colour.
Terminals 5–10 are used for connecting
to the
2N
®
Helios IP Vario
Ethernet. Terminals 3–4 are designed for connecting the electric lock and terminals 1–2
help connect an external 12 V / 2 A DC power supply if no PoE power supply is
available.
The terminal block is included in the package. To adjust an already installed 2N
®
, disconnect it IP from the power supply. Then pull to remove
Helios IP Vario
the terminal block from the printed circuit board.
Insert the wires under the respective terminals.
Tighten the terminals using a flat screwdriver.
Replace the terminal block to the printed circuit board.
Caution
Make sure that the cables leading through the 2N
®
Helios IP Vario
cover bottom groove are installed properly. For the correct installation of
the cables refer to Figure 2.7.