2N TELEKOMUNIKACE a.s., www.2n.cz

®

Function:

The

separates galvanically a two-wire Wiegand bus

2N Helios IP Wiegand Isolator

®

in one direction and a status LED signal in the other direction. The module is power
supplied from the Wiegand bus receiver side.

Specifications:

2-wire WIEGAND IN
2-wire WIEGAND OUT
LED IN switched against GND on WIEGAND OUT side
Open LED OUT switched against GND on WIEGAND IN side (up to 24 V / 50 mA)
5 to 16V / 10 mA power supply from Wiegand bus receiver side
500 V DC isolation strength

Connection: