Configuration connector connection, External power supply connection – 2N Helios IP Vario User Manual
Page 27

27
1.
2.
whether the electric lock will be powered from an external or internal power supply.
External Power Supply Connection
If the Ethernet network is not equipped with the PoE technology, you have two
alternative options how to supply power to
.
2N
®
Helios IP Vario
Using a PoE injector, Part No. 91378100.
is then powered
2N
®
Helios IP Vario
through an Ethernet cable as shown in Tab. 1 above.
Using a power adapter, Part No. 91341481E.
The external power supply from a power adapter can be connected to terminals 1 and
2.
Terminal Block Connection for Power Adapter
Figure:
Configuration Connector Connection
The configuration connector is located in the upper part of the printed circuit board.
Use the configuration jumpers to set whether the lock control relay should have a
normally open or normally closed function and whether it should powered internally or
externally.