Ethernet connection, Electric lock connection – 2N Helios IP Vario User Manual
Page 26
26
Ethernet Connection
For the connections and meanings of the wires see the table below. Join UTP cable
wires 4 (blue) and 5 (white-blue) and attach them under terminal 6 on 2N
®
Helios IP
In the same way, join wires 7 and 8 and place them under terminal 5 of
Vario
2N
®
.
Helios IP Vario
Terminal Block Connections
Figure:
Electric Lock Connection
The electric lock can be connected to terminals 3 and 4 of terminal block X2.
Terminal Block Connection for Electric Lock
Figure:
Terminals 3 and 4 are connected to a relay on the
board. The
2N
®
Helios IP Vario
relay terminals may act as normally open or normally closed contacts. Configuration is
performed through the configuration connector X1 as described in the
Configuration Connector Connection subsection. Set on the configuration connector