GROUP S.P.A.

MT CT 01

16

Relay controls
With the microtelephone lifted, it is possible to activate the following relay outputs:

Table 4: Description of the relays present on card 2909

Adjustment of external unit volume
The sound of the entry phone interface has been designed in full-duplex mode, according to which the person
speaking can also listen to their interlocutor. It has volumes preset by Comelit , and once a conversation with the
external unit is set up, it is in nay case possible to adjust them directly from the telephone by using buttons 1 – 7 – 3
– 9, according to the method shown in the figure below. 17 adjustment levels are possible, and each time the button
is pressed, the volume is changed by 1 level. It is necessary to digit number 2 to store the volume levels reached.

TERMINAL

DESCRIPTION

POWER

COMTEL BCA

NOTES

N1 – C1

“Door Opener”

Relay Max

#

The output can be configured

Control

7 A

as bistable or as monostable.

80Vdc –

This output can be activated

50Vrms

remotely remote on a call from

the telephone line.

N2 – C2

“Stair Lights”

Relay Max

*

The output can be configured as:

control

1A -

- Bistable or as monostable.

24Vdc –

- Internal Lighting-up use or generic use.

120Vrms

If configured as Internal Lighting-up,

the output cannot be activated

remotely with the Relay Remote

Check service.

N3 – C3

“Gate opener”

Relay Max

5

The output can be configured as

1A -

bistable or as monostable.

24Vdc –

This output can be activated

120Vrms

remotely remote on a call from the

telephone line.

#

9

8

7

4

5

6

1

2

3

To increase the
volume in the
External unit –
Extension branch
direction

To increase the volume
in the
Extension branch –
External unit direction

Storage of the
volumes reached.

To decrease the volume
in the
Extension branch –
External unit

To decrease the volume
in the External unit –
Extension branch
direction

Advertising