4 sequence diagram – INFICON PSG55x ATM to Medium Vacuum Gauge (Profibus) User Manual

Page 18

Advertising
background image

18

tira56e1 (2010-02) PxG55x.cp

The following sequence diagram contains an example parameter request by the
cyclic DP master in order to illustrate the application of parameter channel.

AK(RS) = 0

PxG55x

DP-Master

AK(RS) = 0

AK (IS) = 1

AK(RS) = 1

AK (IS) = 1

Parameter

Request

(Client)

AK(RS) = 0

AK (IS) = 1

AK(RS) = 0

AK (IS) = 0

AK(RS) = 0

Store

Data

AK (IS) = 0

AK(RS) = 0

Parameter

Request

(Server)

AK(IS) = 0

AK(IS) = 0

Fetch

Data

The master must mark the end of the instruction cycle by setting AK to zero. Only
after that, a new instruction/response cycle may be started.

4.3.4 Sequence Diagram