13 exception detail warning (id 28) – INFICON PSG55x ATM to Medium Vacuum Gauge (Profibus) User Manual

Page 29

Advertising
background image

tira56e1 (2010-02) PxG55x.cp

29

If one of bits 4…6 is set in the Exception Status, the current warning can be read in
the parameter "Exception Detail Warning". Depending on the device configuretion
specified by instrument-type the "Exception Detail Warning" parameter consists of
a total of 9 or 11 bytes that inform on the warning status of the gauge.

The parameter contains an array of 11 bytes, which are assigned as follows:

Byte

no

Name

Description

Value

Common Exception Detail Warning

0

Size

Number of subsequent bytes
used for description the warning
(simple, UINT8, 1 byte)

2

1

Detail 0

Error message
(simple, UINT8, 1 byte)

→ table  28

2

Detail 1

Error message
(simple, UINT8, 1 byte)

→ table  28

Device Exception Detail Warning

3

Size

Number of subsequent bytes
used for description the warning

5

4 OneOfN

Status

Extension

Status extension
(simple, UINT8, 1 byte)

Status extension

(ID 102) of PCG55x

Transducer Block

5 Detail

0

6 Detail

1

Error message
(array, UINT8, 2 bytes)

Sensor Warning

(Inst. 1, ID 104) of

PCG55x Transducer

Block

7 Detail

2

8 Detail

3

Error message
(array, UINT8, 2 bytes)

Sensor Warning

(Inst. 2, ID 104) of

PCG55x Transducer

Block

Manufacturer Exception Detail Warning

9

Size

Number of subsequent bytes
used for description of the
warning
(simple, UINT8, 1 byte)

1

10 Detail

Error

message

(simple, UINT8, 1 byte)

→ table  28

7.1.13 Exception Detail

Warning (ID 28)

PCG55x

Advertising
This manual is related to the following products: