The figure below shows the state chart of the discrete output function block.

State name

Description

Available

This is the initial state after power on. The Device Block is
in Executing state (

→  32).

Idle

This state cuts the signal flow between the SetpointValue
of the certain Discrete Output function block instance and
its dedicated underlying actuation hardware. The behavior
is according the IdleActionSelector parameter.

Ready

The connection between the SetpointValue parameter of
the certain Discrete Output function block instance and its
dedicated underlying actuation hardware is recovered. The
instance is waiting for new SetpointValue parameter
values.

Run

The instance is working in its dedicated way.

Recoverable Fault

There is a temporary fault. The reason is device and
manufacturer specific.

Unrecoverable
Fault

There is a fault with no automatic return. This fault can
force a Critical Fault according to page 32 or refers to the
certain instance only.

Executing

This state is defined on page 32, i.e. the state machine is
working in this device state only.