Fertilizer option cable, Temperature sensor cable, Fertilizer option cable -36 – Kinze 4900 Front Folding Planter Rev. 5/14 User Manual

Page 118: Temperature sensor cable -36

Advertising
background image

M0247-01

Model 4900

6-36

Rev. 5/14

TM

Lubrication and Maintenance

FERTILIzER OPTION CAbLE

B
A

B
A

B

A

B

A

1 2 3 4 5 6

B A

A B

B A

A B

Row Module (MDM)

Left Valve (VL)

Left Switch (SL)

Right Valve (VR)

Right Switch (SR)

VL

SL

VR

SL

P/N A19400

Signal

Wire Gauge

Color

RM

VL

SL

VR

SR

Power

16

Red

1

A

-

A

-

Left Fertilizer Switch

16

Green

4

-

B

-

-

Right Fertilizer Switch

16

Blue

5

-

-

-

B

Left Fertilizer Valve

16

Light Blue

2

B

-

-

-

Right Fertilizer Valve

16

Violet

3

-

-

B

-

Ground

16

Black

6

-

A

-

A

P/N A19419

Signal

Wire Gauge

Color

TEMP

RM

12VDC Sen Supply

18

Brown

1

5

Ground

18

Blue

2

2

Signal

18

Yellow/Green

3

6

TEMPERATURE SENSOR CAbLE

Temperature (TEMP)

Row Module (RM)