Troubleshooting

SOLENOID VALVE

PRObLEM

POSSIbLE CAUSE

SOLUTION

No solenoids operate.

Low voltage.

Must be connected to 12 volt DC only.

Negative ground.

Blown fuse.

Replace control console fuse with AGC-15 amp.

Battery connection.

Clean and tighten.

Wiring harness damaged.

Repair or replace.

One solenoid valve will not

operate.

Bad switch.

Replace on control panel.

Cut wire in harness.

Locate and repair.

Bad coil.

Replace.

Poor connection at coil.

Check.

Valve operating when not

energized.

Valve stem stuck open.

Replace cartridge.

O-ring leaking.

Install new O-ring kit.

Foreign material under poppet.

Remove and clean cartridge.