Lubrication and Maintenance

Clean and grease PTO shaft coupling each time pump
is installed.

Apply coating of high-speed industrial coupling grease,
such as Chevron

®

Coupling Grease meeting AGMA

CG-1 and CG-2 Standards to extend shaft spline life.

LIqUID FERTILIzER PISTON PUMP CRANKCASE OIL LEVEL

Check crankcase oil daily and maintain at oil level
check plug. Fill as needed with EP 90 weight gear oil.
Total oil capacity is approximately ¾ pint.

Refer to operator and instruction manual supplied with
pump and flow divider for more information.

Piston Pump Oil Fill and Check Plug Locations

Fill plug

Check plug

PTO SHAFT COUPLING

PTO Pump Installed

LIqUID FERTILIzER CENTRIFUGAL PUMP

Pumps are equipped with factory lubricated bearings
and seals and require no further maintenance.

Neutralize chemicals and flush pump afer each use to
prevent corrosion.

Refer to operator and instruction manual supplied with
pump for more information.