Safety instructions
Residual hazards
l
39
EDK94PNE245 DE/EN/FR/ES/IT 2.0
2.2
Residual hazards
Protection of persons
ƒ
Before working on the power supply module, check that all power terminals are
deenergised
– because the power terminals L1, L2, L3, +UG, −UG, Rb1, Rb2, X109 and X110 carry
hazardous voltages for at least 3 minutes after mains disconnection.
– because the power terminals carry hazardous voltages even when only the mains
voltage is applied.
Device protection
ƒ
Connect/disconnect all pluggable terminals only in deenergised condition!
ƒ
Detach the power supply modules from the AC mains or from the axis modules only
in deenergised condition!
ƒ
The unit only functions properly when the 24 V supply is switched on!