2 design of the cables, Design of the cables, Wiring the device – Lenze E94APNExxx4 User Manual

Page 53

Advertising
background image

Wiring the device

Wiring

Design of the cables

5

l

53

EDK94PNE245 DE/EN/FR/ES/IT 2.0

5.3.2

Design of the cables

ƒ

The cables used must comply with the approvals required for the location (e.g. UL).

ƒ

It is imperative to comply with the regulations concerning minimum cross−sections
of PE conductors. The cross−section of the PE conductor must be at least as large as
the cross−section of the power connections.

ƒ

The effectiveness of a shielded cable is reached by:
– Providing a good shield connection through large−surface shield contact.
– Using only braided shields with low shield resistance made of tin−plated or

nickel−plated copper braid.

– Using braided shields with an overlap rate > 70 % and an overlap angle of 90 °.
– Keeping unshielded cable ends as short as possible.

Use system cables or shielded cables for these connections:

ƒ

External brake resistor (

, Mounting Instructions of the brake resistor)

The following connections need not be shielded:

ƒ

Mains

ƒ

24 V supply

ƒ

Digital signals (inputs and outputs)