3 technical data, 1 general data and operating conditions, Technical data – Lenze E94APNExxx4 User Manual

Page 42: General data and operating conditions, 3technical data

Advertising
background image

Technical data

General data and operating conditions

3

l

42

EDK94PNE245 DE/EN/FR/ES/IT 2.0

3

Technical data

3.1

General data and operating conditions

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

Approval

In preparation: UL

UL 508C

Industrial Control Equipment, file no. 132659

Supply system data

Supply forms

With earthed

*

point

Unrestricted use

IT systems

Unrestricted use
Observe instructions about special measures concerning the
connected axis controllers!

Noise emission

EN 61800−3

Conducted: cannot be specified because dependent on the
conditions present in the interconnected system

Radiation: category C3

Noise immunity (according to requirements of EN 61800−3)

Electrostatic discharge
(ESD)

EN 61000−4−2

8 kV for air discharge,
4 kV for contact discharge to housing

Radio frequency

Conducted

EN 61000−4−6

150 kHz ... 80 MHz, 10 V/m 80 % AM (1 kHz)

Radiation (housing)

EN 61000−4−3

80 MHz ... 1000 MHz, 10 V/m 80 % AM (1 kHz)

Protection of persons and equipment

Enclosure

EN 60529

IP 20

Not in the wiring area of
the lower terminals

NEMA 250

Protection against contact to
type 1

Insulation resistance

EN 61800−5−1

Overvoltage category III
Derating at and above 2000 m amsl: overvoltage category II

Insulation of control
circuits

EN 61800−5−1

Safe mains isolation by double/reinforced insulation.

Short−circuit strength

EN 61800−5−1

DC−bus connection: not short−circuit−proof
Brake resistor connection: fully short−circuit proof
Control connections: fully short−circuit proof

Leakage current

EN 61800−5−1

> 3.5 mA

Observe regulations and
safety instructions!

Cyclic mains switching

Cyclic mains switching of 5 times within 5 minutes is
permitted without restrictions.

Mounting conditions

Mounting place

In the control cabinet

Mounting position

Vertical

Mounting clearances

Above/below

³ 80 mm / ³ 120 mm

Observe the device−related
notes on mounting.

To the sides

Side−by−side mounting without
any clearance

Advertising