3 wiring, 1 connecting busbars, Wiring – Lenze E94APNExxx4 User Manual

Page 52: Connecting busbars, Wiring the device

Advertising
background image

Wiring the device

Wiring
Connecting busbars

5

l

52

EDK94PNE245 DE/EN/FR/ES/IT 2.0

5.3

Wiring

5.3.1

Connecting busbars

SSP94PN401

Fig.5−2

Example: connecting busbars to DC power supply module

Proceed as follows to connect the busbars:

1. If devices of the interconnected system have already been in operation:

– Ensure that the power supply system is switched off by checking the voltage at the

supply terminals.

– If necessary, switch off the power supply and wait at least 3 minutes.

2. Loosen the busbar screws but do not remove them completely.

3. Push the busbars as far as possible to the left towards the adjacent busbar.

– Ensure that there is good contact to the adjacent busbar.

4. Tighten the busbar screws.

– Tightening torque: 3.2 ... 3.5 Nm (28 ... 31 lb−in).

5. Screw all components onto the mounting plate.

– Tightening torque: 3.4 Nm (30 lb−in).

Advertising