Technical data

Electrical data

3

l

44

EDK94PNE245 DE/EN/FR/ES/IT 2.0

3.2

Electrical data

Basis of the data

Mains

Voltage

U

LN

[V]

Voltage range

U

LN

[V]

Frequency range

f [Hz]

3/PE AC

230

180 − 0 % ... 264 + 0 %

45 − 0 % ... 65 + 0 %

3/PE AC

400

320 − 0 % ... 440 + 0 %

45 − 0 % ... 65 + 0 %

3/PE AC

500

400 − 0 % ... 550 + 0 %

45 − 0 % ... 65 + 0 %

Input data

Voltage

Frequency

Current [A]

Number of

phases

Type

[V]

[Hz]

max. +45 °C



max. +55 °C



E94APNE1004

230/400/500

50/60

82/82/82

61/61/61

3

E94APNE2454

230/400/500

50/60

200/200/200

150/150/150

3

 Temperature in the control cabinet

Voltage

Continuous input power

Type

[V]

S

L

[kVA]

E94APNE1004

230/400/500

32.6/56.7/70.9

E94APNE2454

230/400/500

79.6/138/173

Output data

Voltage

Frequency

Current [A]

Number of

phases

Type

[V]

[Hz]

max. +45 °C



max. +55 °C



E94APNE1004

325/565/705

0 (DC)

100/100/100

75/75/75

2

E94APNE2454

325/565/705

0 (DC)

245/245/245

184/184/184

2

 Temperature in the control cabinet

Voltage

Output power X109, X110, +UG, −UG

Type

[V]

With mains filter P

aDC

[kW]

Without mains filter P

aDC

[kW]

E94APNE1004

325/565/705

27.9/48.6/60.8

20.8/36.2/45.2

E94APNE2454

325/565/705

68.5/119/149

51/88.6/111

Power loss P

V

[W]

Type

Total (when operating with I

aN

)

Constant (control electronics only)

E94APNE1004

230

7

E94APNE2454

550

7

Advertising