The PositionServo 940 buffers encoder feedback from P4 to P3. Encoder Feedback
channel A on P4, for example, is Buffered Encoder Output channel A on P3. The Hall
sensors from the motor must be wired to the 15-pin connector (P4).

STOP!

Use only +5 VDC encoders. Do not connect any other type of encoder
to the PositionServo 940 reference voltage terminals. When using a
front-end controller, it is critical that the +5 VDC supply on the front-
end controller NOT be connected to the PositionServo 940’s +5 VDC
supply, as this will result in damage to the PositionServo 940.

NOTE

The PositionServo 940 encoder inputs are designed to accept
differentially driven hall signals. Single-ended or open-collector
type hall signals are also acceptable by connecting “HA+”, “HB+”,
“HC+” and leaving “HA-,HB-,HC-” inputs unconnected. You do not
need to supply pull-up resistors for open-collector hall sensors.
The necessary pull-up circuits are already provided.

Encoder connections (A, B, and Z) must be full differential.
PositionServo doesn’t support single-ended or open-collector type
outputs from the encoder.

An encoder resolution of 2000 PPR (pre-quadrature) or higher is
recommended.

Using P4 as second encoder input for dual-loop operation.

P4 can be used as a second loop encoder input in situations where the motor is
equipped with a resolver as the primary feedback. If such a motor is used, the drive
must have a resolver feedback option module installed. A second encoder can then be
connected to the A and B lines of the P4 connector for dual loop operation. Refer to
“Dual-loop Feedback Operation” for details (Section 6.4).
P4 PIN ASSIGNMENTS (ENCODER)

Pin

Name

Function

1

EA+

Encoder Channel A+ Input

(1)

2

EA-

Encoder Channel A- Input

(1)

3

EB+

Encoder Channel B+ Input

(1)

4

EB-

Encoder Channel B- Input

(1)

5

EZ+

Encoder Channel Z+ Input

(1)

6

EZ-

Encoder Channel Z- Input

(1)

7

GND

Drive Logic Common/Encoder Ground

8

SHLD

Shield

9

PWR

Encoder supply (+5VDC)

10

HA-

Hall Sensor A- Input

11

HA+

Hall Sensor A+ Input

12

HB+

Hall Sensor B+ Input

13

HC+

Hall Sensor C+ Input

14

HB-

Hall Sensor B- Input

15

HC-

Hall Sensor C- Input

(1)

See Note 1, Section 4.1.7 - Connector and Wiring Notes