Operation – Lenze S94P01B2 User Manual

Page 55

Advertising
background image

S94P01B2

53

Operation

I-Gain set OK

No error between Commanded steady state

velocity and Actual steady state velocity with

excellent stability.

I-Gain set too HIGH

Additional overshoot and oscillations are

starting to occur. Steady state velocity

regulation

Step 4: Check Motor Currents

Finally check the motor currents on the Oscilloscope. Make the following settings to the
oscilloscope.

Channel 1:

Signal

= “Phase Current RMS”

Scale

= as appropriate to peak current limit set in drive parameters (MotionView)

Timebase: = as appropriate to “Period” value of Indexer Program

Trigger:

= Channel 2, Rising Edge

Level:

= 10 RPM

Observe the waveforms to insure there are no significant oscillations. Reduce the gains
values if necessary.

The current waveform should be showing spikes of current during acceleration /
deceleration and steady state current during any steady state velocity. The maximum
value (peak value) of the current waveform is shown at the top of the oscilloscope
screen. This maximum value can be compared to the drive nominal current and peak
current settings to check how much of the motors potential performance is being used
and if optimum performance is being achieved.

Advertising