8 diagnostics, 1 display, 8diagnostics – Lenze S94P01B2 User Manual

Page 67: Diagnostics

Advertising
background image

S94P01B2

65

Diagnostics

8

Diagnostics

8.1

Display

The PositionServo 940 drives are equipped with a diagnostic LED display and 3 push
buttons to select displayed information and to edit a limited set of parameter values.

Parameters can be scrolled by using the “UP” and “DOWN” (

) buttons. To view a

value, press “Enter”( ). To return back to scroll mode press “Enter” again.

After pressing the ”Enter” button on editable parameters, the yellow LED “C” (see figure
in the next section) will blink indicating that parameter value can be changed. Use “UP”
and “DOWN” buttons to change the value. Press “Enter” to store new setting and return
back to scroll mode.

Display

Description

StAt

current drive status - to view:

run

- drive running

diS

- drive disabled

F_

XX - drive fault. Where XX is the fault code (section 8.3.1)

H

x.xx

Hardware revision (e.g. H2.00)

F

x.xx

Firmware revision (e.g. F2.06)

bAUd

RS232/RS485(normal mode) baud rate - to set

selects from 2400 to 115200 baudrates

Adr

Drive’s address - to set

sets 0 - 31 drive’s address

FLtS

Stored fault’s history - to view

scroll through stored faults F0XX to F7XX, where XX is the fault

code (section 7.3.1)

Ht

Heatsink temperature - to view
Shows heatsink temperature in ºC if greater than 40ºC. Otherwise
shows “LO” (low).

EnC

Encoder activity - to view
Shows primary encoder counts for encoder diagnostics activity

HALL

Displays motor’s hall sensor states - to view
Shows motor hall states in form XXX , where X is 1 or 0 - sensor logic
states.

buS

Displays drive DC bus voltage - to view
Shows DC bus voltage value

Curr

Displays motor’s phase current (RMS)
Shows current value if drive is enabled, otherwise shows “

DiS