Reference – Lenze S94P01B2 User Manual

Page 64

Advertising
background image

S94P01B2

62

Reference

Mandatory Parameter Settings:
These parameters are required to be set prior to running the drive.

Folder/Sub-Folder

Parameter Name

Description

Parameters

Drive Mode

Set to [Velocity]

Reference

Set to [External]

Enable Velocity Accel / Decel Limits

Enable Ramp rates for Velocity Mode

Velocity Accel Limit

Set required Acceleration Limit for Velocity command

Velocity Decel Limit

Set required Deceleration Limit for Velocity command

IO / Analog IO

Analog Input (Velocity Scale)

Set to required velocity per 1 volt input from controller

Analog Input Dead band

Set zero velocity Dead band in mV

Analog Input Offset

Set Analog Offset for velocity Reference

IO / Digital IO

Enable Switch Function

Set to [Run]

Compensation

Velocity P-Gain

Set P-Gain for Velocity loop

(see tuning section)

Velocity I_Gain

Set I-Gain for Velocity loop

Gain Scaling

Set Gain Scaling Parameter

Optional Parameter Settings:
These parameters may require setting depending on the control system implemented.

Folder / Sub-Folder

Parameter Name

Description

Parameters

Resolver Track

PPR for simulated encoder on 941 Resolver drive

IO / Digital IO

Output 1 Function

Set to any pre-defined function required

Output 2 Function

Set to any pre-defined function required

Output 3 Function

Set to any pre-defined function required

Output 4 Function

Set to any pre-defined function required

IO / Analog IO

Adjust Analog Input

Tool that can be used to learn analog input level

Analog Output

Set to any pre-defined function required

Analog Output Current Scale Set to scale analog output if current value is selected

Analog Output Velocity Scale Set to scale analog output if velocity value is selected

Limits / Velocity Limits

Zero Speed

Set bandwidth for activation of Zero Speed Output

At Speed

Set Target Speed for activation of At Speed Output

Speed Window

Set bandwidth for activation of At Speed Output