3 motor set-up, Interface – Lenze S94P01B2 User Manual

Page 30

Advertising
background image

S94P01B2

28

Interface

4.5.3 Motor Set-up

Once you are connected to the PostionServo 940 via MotionView a “Parameter Tree”
will appear in the “Parameter Tree Window”. The various parameters of the drive are
shown here as folders and files. If the “Motor” folder is selected, all motor parameters
can be viewed in the “Parameter View Window”. To view selected motor parameters or
to select a new motor click the section marked “CLICK HERE TO CHANGE”.

S911

MotionView’s “Motor Group” folder and its contents

NOTE

If the drive is ENABLED, a new motor cannot be set. You can only set a
new motor when the drive is DISABLED.

To View selected motor parameters or to make a new motor selection:
• Click “Click here to change the motor” from the Parameter View Window (see figure

above). If you are just viewing motor parameters click Cancel on Motor Parameters
dialog when done to dismiss the dialog box.

• Select motor Vendor from the right list box and desired motor from the left list box.

• If you will be using a “custom” motor (not listed in our motor database) go to ”Using a

custom motor” topic in the next section.

• Finally, click the OK button to dismiss the dialog and return to MotionView’s main program.

Advertising