Parameters

5.3.19 Group ID

Refer to the Programmer’s manual for details. This parameter is only needed for
operations over an Ethernet network.

5.3.20 Enable Switch Function

If set to “Run”, input IN_A3 (P3.29) acts as an “Enable” input when the user program
is not executing. If the user program is executing, the function will always be “Inhibit”
regardless of the setting. This parameter is needed so the drive can be Enabled/
Disabled without running a user’s program.

5.3.21 User Units

This parameter sets up the relationship between User Units and motor revolutions.
From here you can determine how many User Units there is in one motor revolution.
This parameter allows the user to scale motion moves to represent a desired unit of
measure, (inches, meters, in/sec, meters/sec, etc).

For example:
A linear actuator allows a displacement of 2.5” with every revolution of the motor’s shaft.

Units = Units / Revolutions
Units = 2.5 Inches / Revolution
Units = 2.5

5.4

Communication

5.4.1 IP Setup

This action button opens dialog for TCP/IP related parameters setup.

5.4.2 RS-485 Configuration

This parameter sets how the optional RS485 interface will function. The RS485
interface can be configured for normal operation (programming and diagnostics using
MotionView software) or as a Modbus RTU slave. See section 4.4 for comm interfaces.

5.4.3 Modbus Baud Rate

This parameter sets the baud rate for RS485 interface in Modbus RTU mode. When
the drive is operating in normal mode the baud rate is set to the same setting as the
RS232 interface.

5.4.4 Modbus Reply Delay

This parameter sets the time delay between the drives reply to the Modbus RTU master.
This delay is needed for some types of Modbus masters to function correctly.

5.5

Analog I/O

5.5.1 Analog Output

The PositionServo 940 has one analog output with 10-bit resolution on P3.23. The
signal is scaled to ± 10V. The analog output can be assigned to following functions:

Not Assigned

Phase R current

Iq current (Torque component)

Phase current RMS

Phase S current

Id current (Direct component)

Phase current Peak

Phase T current

Motor Velocity