Safety instructions

Safety instructions for the installation according to UL or UR

1

l

42

EDKCSDK002 DE/EN/FR 1.1

1.3

Safety instructions for the installation according to U

L

or U

R

K

Warnings!

General markings:

ƒ

Use 60/75 °C or 75 °C copper wire only.

ƒ

Maximum ambient temperature 55 °C, with reduced output
current.

Terminal tightening torque of lb−in (Nm)

ƒ

x23
– 10.6 ... 13.3 lb−in (1.2 ... 1.5 Nm)

ƒ

x26
– 4.4 ... 7.1 lb−in (0.5 ... 0.8 Nm)

Wiring diagram AWG

ƒ

x23
– AWG 12 ... AWG 8

ƒ

x26
– AWG 24 ... AWG 12