Mechanical installation – Lenze ECSDKxxx User Manual
Page 50
Advertising
Mechanical installation
Mounting with thermal separation (push−through technique)
Dimensions
l
50
EDKCSDK002 DE/EN/FR 1.1
Dimensions of mounting cutout
)
Note!
With ECSZS000X0B001 shield mounting kit:
ƒ
Clearance below the mounting cutout > 220 mm
³
60
mm
³
90
mm
a1
a1
b1
b1
1
2
0
c1
h
d
c1
g
g
ECSXA063
Fig.8−2
Dimensions of mounting cutout
0
Mounting cutout for size
0
1
Mounting cutout for size
1
2
Mounting plate
Capacitor module
Dimensions [mm]
Type
Size
a1
b1
c1
d
g
h
ECSDK001
0
78.5
197
75
250
M5
10.5
ECSDK002
1
121.5
Advertising