Electrical installation

Wiring

Operation with ECSxE power supply module

4

l

59

EDKCSDK002 DE/EN/FR 1.1

4.4

Wiring

Install the capacitor module between the power supply module and the axis mo-
dule(s).
If the total cable length in the DC−bus connection is longer than 5 m, install the ca-
pacitor module as close as possible to the axis module with the highest power.

4.4.1

Operation with ECSxE power supply module

(

Stop!

ƒ

Permanently bridge the charging current limitation (X26) of the
capacitor module (X26 = HIGH).

ƒ

Only release the controller (X6/SI1 = HIGH) if the power supply
module ECSxE displays "Ready for operation" (X6/DO1 = HIGH).

t [s]

HIGH (1)

LOW (0)

ECSx

: X6/SI1

ü

ECSxE: X6/DO1

t [s]

100 %

0 %

t [s]

HIGH (1)

LOW (0)

ECSxK: X26 (24 V DC)

ECSxE: X6/DI1
ECSxE: X6/DI2

t [s]

HIGH (1)

LOW (0)

K1

U

ZK

ECSXK010

Fig.9−1

Level/time diagrams for operation with ECSxE power supply module

ECSx

ü

Axis module of series ECS

ECSxE

Power supply module of series ECS

U

ZK

DC−bus voltage

ECSxK

Capacitor module of series ECS

K1

Mains contactor