Configuration

UOOu_^MTMO

7-5

L

Code

IMPORTANT

Possible settings

Name

Code

IMPORTANT

Info

Selection

Lenze

Name

C056* Controller load

Only display

C061* Heat sink

temperature

Only display

C079 Oscillation damping

Is not transferred when
transferring

822X/824X

5

0

{1}

80

transferring
parameters via the
operating module.

C088 Rated motor current

821X/822X/824X

*

0.0 ... 1.2 ¡ rated output current

* depends on the unit

C091 Motor cos

j

821X/822X/824X

*

0.4

{0.1}

1.0

* depends on the unit

C093* Type

Only display

820X

820X

821X

821X

822X/824X

822X

C099* Software version

Only display

820X

82 1x

(Software 1x)

821X

82 2x

(Software 2x)

82 1x

(Software 1x)

822X/824X

82 1x

(Software 1x)

C105 Deceleration time

quick stop

821X/822X/824X

5.00

0.00

{0.01s}

999.00

C106 Holding time for

autom. DC injection
brake

820X

0.00

0.00

{0.01s}

50.00

821X/822X

824X

0.02

0.00

{0.01s}

999.00

C108* Gain (C111)

820X

220

0

{1}

255

821X

128

0

{1}

255

822X/824X

128

0

{1}

255

C111

¿ Monitor signal

-0-

-0-

Field frequency

-1-

Controller load

-2-

Motor current

-3-

DC-bus voltage

C117

¿ Function relay K2

822X/824X

-0-

-0-

Ready for operation

-1-

TRIP fault message

-2-

Motor is running

-3-

Motor is running / CW rotation

-4-

Motor is running / CCW rotation

-5-

Field frequency f

d

= 0

-6-

f

dSet

reached

-7-

Q

min

reached

-8-

I

max

reached

-9-

Overtemperature (

J

max

-10

°C)

-10-

TRIP or Q

min

or IMP

-11-

PTC warning

Show/Hide Bookmarks