Safety information

2.1

General safety information

Safety and application notes for controllers

EíçW içïJsçäí~ÖÉ aáêÉÅíáîÉ TPLOPLbb`F

1. General
During operation, drive controllers may have, according to their

type of protection, live, bare, in some cases also movable or

rotating parts as well as hot surfaces.
Non-authorized removal of the required cover, inappropriate use,

incorrect installation or operation, creates the risk of severe injury

to persons or damage to material assets.
Further information can be obtained from the documentation.
All operations concerning transport, installation, and

commissioning as well as maintenance must be carried out by

qualified, skilled personnel (IEC 364 and CENELEC HD 384 or DIN

VDE 0100 and IEC report 664 or DIN VDE 0110 and national

regulations for the prevention of accidents must be observed).
According to this basic safety information qualified skilled

personnel are persons who are familiar with the erection,

assembly, commissioning, and operation of the product and who

have the qualifications necessary for their occupation.

2. Application as directed
Drive controllers are components which are designed for

installation in electrical systems or machinery.
When installing in machines, commissioning of the drive

controllers (i.e. the starting of operation as directed) is prohibited

until it is proven that the machine corresponds to the regulations

of the EC Directive 89/392/EEC (Machinery Directive); EN 60204

must be observed.
Commissioning (i.e. starting of operation as directed) is only

allowed when there is compliance with the EMC Directive

(89/336/EEC).
The drive controllers meet the requirements of the Low Voltage

Directive 73/23/EEC. The harmonized standards of the prEN

50178/ DIN VDE 0160 series together with EN 60439-1/DIN VDE

0660 part 500 and EN 60146/DIN VDE 0558 are applicable to

drive controllers.
The technical data and information on the connection conditions

must be obtained from the nameplate and the documentation and

must be observed in all cases.

3. Transport, storage
Notes on transport, storage and appropriate handling must be

observed.

Climatic conditions must be observed according to prEN 50178.

4. Erection
The devices must be erected and cooled according to the

regulations of the corresponding documentation.
The drive controllers must be protected from inappropriate loads.

Particularly during transport and handling, components must not

be bent and/or isolating distances must not be changed. Touching

of electronic components and contacts must be avoided.
Drive controllers contain electrostatically sensitive components

which can easily be damaged by inappropriate handling.

Electrical components must not be damaged or destroyed

mechanically (health risks are possible!).

5. Electrical connection
When working on live drive controllers, the valid national

regulations for the prevention of accidents (e.g. VBG 4) must be

observed.
The electrical installation must be carried out according to the

appropriate regulations (e.g. cable cross-sections, fuses, PE

connection). More detailed information is included in the

documentation.
Notes concerning the installation in compliance with EMC - such

as screening, grounding, arrangement of filters and laying of

cables - are included in the documentation of the drive controllers.

These notes must also be observed in all cases for drive

controllers with the CE mark. The compliance with the required

limit values demanded by the EMC legislation is the responsibility

of the manufacturer of the system or machine.

6. Operation
Systems where drive controllers are installed must be equipped, if

necessary, with additional monitoring and protective devices

according to the valid safety regulations, e.g. law on technical

tools, regulations for the prevention of accidents, etc.

Modifications of the drive controllers by the operating software are

allowed.
After disconnecting the drive controllers from the supply voltage,

live parts of the controller and power connections must not be

touched immediately, because of possibly charged capacitors. For

this, observe the corresponding labels on the drive controllers.
During operation, all covers and doors must be closed.

7. Maintenance and servicing
The manufacturer’s documentation must be observed.

This safety information must be kept!

The product-specific safety and application notes in these

Operating Instructions must also be observed!