1. Check for damaged, broken, or missing parts.

2. Verify the On/Off switch is in the OFF position.

3. Before connecting the MK-660 Saw to a power supply, be sure the voltage, cycle

and phase of the job site power source meet the requirements of the table below:

(A) Ensure the ON/OFF Switch is in the OFF position

(B) Plug MK-660 Saw into the GFCI

(C) Plug the GFCI into the power source

VOLTAGE:

120v

CYCLE:

60hz

PHASE:

1-phase

MK-660 tile saw

OPeRatiON

MK-660 saw setUP FOR OPeRatiON

CaUtiON

If using a portable generator to provide power, ensure the generator meets the following minimum

requirements: 8 KW 120/240 volts

66.7/33.3 amps

Single Phase

4. If using an extension power cord, make sure the length and wire gauge

correspond to the requirements listed in the table on page 10. An extension

power cord that is too small in wire gauge (diameter), or too long in length, will

cause the motor to overheat and could cause premature failure.

5. Use an approved Ground Fault Circuit Interrupter (GFCI).

6. Do not cover the motor vents as this could lead to motor overheating.

NOte:

NOte:

PORtaBle GeNeRatOR

In order to avoid breaker tripping, a 20-amp circuit breaker should be used.

MK Diamond has available, as an accessory item, (Part # 152610) a plug-in GFCI that

may be plugged into a properly installed and grounded 3-pole outlet.