MK Diamond MK-660 User Manual
Page 36

36
BlaDe stOPs tURNiNG
(A)
Allow motor to cool and
depress motor Overload
Reset Switch
(C)
Check Ground Fault Circuit
Interrupter (GFCI) is not tripped
(B)
Verify all plugs fully installed
MK-660 tile saw
tROUBlesHOOtiNG
(D)
Verify circuit breaker at least
20 amps - if not, move to
20-amp circuit
(F)
Check power source voltage
is 120v - if not 120v, move to
another circuit
(E)
Verify circuit breaker not
tripped if tripped, reset once
Using the proper blade when cutting any material will insure that additional drag
is not induced on the motor thus increasing the amperage draw. Too much drag/
amperage draw can overheat the motor. A sign that the incorrect blade is being
used for the material being cut is if user trips the circuit breaker at the power
supply when cutting the material.
NOte: