D-sub, Waterproof connectors technical characteristics – Northern Connectors Harting D-sub Connectors, Housings & Accessories User Manual

Page 127

Advertising
background image

05

126

D-Sub

M

F

M

F

M

F

M

F

M

F

D-Sub

waterproof connectors

Technical characteristics

Contact arrangement

View from termination side

Mating conditions

as per DIN 41 652

M = Male connector

F = Female connector

37 way

50 way

Number of contacts

9, 15, 25, 37, 50

UL recognized

Working current

5 A

Test voltage

1200 V for 1 minute

between 2 contacts / contact and shell

Clearance and creepage

≥ 1.0 mm

Contact resistance

Straight contact

≤ 10 mΩ

Angled contact

≤ 25 mΩ

Angled contact 50-pole

≤ 35 mΩ

Insulation resistance

between contacts

≥ 5000 MΩ

Dielectric strength

50 kV/mm

Temperature range

-25

O

C … +70

O

C

Protection

IP 67

(per DIN 40 050 / IEC 529)

Termination

Solder cup

max. AWG 20

Solder pin straight

0.6 mm diameter

Solder pin angled

0.6 mm diameter

Material

Shell

Brass, tin plated

Insulator and plastic watertight frame Thermoplastic,

glass-fibre filled, UL 94-V0

Metal watertight frame

Nickel plated zinc die cast

Contact material

Machined copper alloy

Contact surface

Contact zone

S4 = 0.76 µm (30 µinch) Au

or PdNi equivalent

Waterproofing element

Silicone

Mechanical

Mating cycles

≥ 500

Mating force per signal contact

≤ 3.4 N

Unmating force per signal contact ≥ 0.2 N

9 way

15 way

25 way

Advertising