D-sub – Northern Connectors Harting D-sub Connectors, Housings & Accessories User Manual
Page 176
05
175
D-Sub
D-Sub
DIN 41 652 · CECC 75 301-802
9-37
50
Press-in, straight with grounding press-in board locks
Number of contacts
9--50
Identification
Drawing
Dimensions in mm
Male connector
9 – 25 contacts
Female connector
9 – 37 contacts
Board drillings
a b
g
h
9 31.00 24.90 4 x 2.74 = 10.96 3 x 2.74 = 8.22
15 39.30 33.20 7 x 2.74 = 19.18 6 x 2.74 = 16.44
25 53.10 47.00 12 x 2.76 = 33.12 11 x 2.76 = 30.36
37 69.65 63.55 18 x 2.76 = 49.68 17 x 2.76 = 46.92
50 67.00 61.10 16 x 2.76 = 44.16 15 x 2.76 = 41.40
X
Y
Z
6.0 ± 0.2
4.20 ± 0.2
3.5 max.
5.7 ± 0.2
4.35 ± 0.2
3.9 max.
Female connector
50 contacts
Mating face acc. to: DIN 41 652 · CECC 75 301-802 · IEC 60 807
contact grounding board lock
M3 or
4 - 40 UNC
fitted screw locks
4 - 40 UNC
M3 or
4 - 40 UNC
fitted screw locks
4 - 40 UNC
M3 or
4 - 40 UNC
fitted screw locks
4 - 40 UNC
mark for 5.7 mm version
No. 1
contact
No. 1
contact
contact grounding
board lock
Plated through hole