D-sub – Northern Connectors Harting D-sub Connectors, Housings & Accessories User Manual

Page 176

Advertising
background image

05

175

D-Sub

D-Sub

DIN 41 652 · CECC 75 301-802

9-37

50

Press-in, straight with grounding press-in board locks

Number of contacts

9--50

Identification

Drawing

Dimensions in mm

Male connector

9 – 25 contacts

Female connector

9 – 37 contacts

Board drillings

a b

g

h

9 31.00 24.90 4 x 2.74 = 10.96 3 x 2.74 = 8.22
15 39.30 33.20 7 x 2.74 = 19.18 6 x 2.74 = 16.44
25 53.10 47.00 12 x 2.76 = 33.12 11 x 2.76 = 30.36
37 69.65 63.55 18 x 2.76 = 49.68 17 x 2.76 = 46.92
50 67.00 61.10 16 x 2.76 = 44.16 15 x 2.76 = 41.40

X

Y

Z

6.0 ± 0.2

4.20 ± 0.2

3.5 max.

5.7 ± 0.2

4.35 ± 0.2

3.9 max.

Female connector

50 contacts

Mating face acc. to: DIN 41 652 · CECC 75 301-802 · IEC 60 807

contact grounding board lock

M3 or

4 - 40 UNC

fitted screw locks

4 - 40 UNC

M3 or

4 - 40 UNC

fitted screw locks

4 - 40 UNC

M3 or

4 - 40 UNC

fitted screw locks

4 - 40 UNC

mark for 5.7 mm version

No. 1

contact

No. 1

contact

contact grounding

board lock

Plated through hole