D-sub, Min. insertion loss – Northern Connectors Harting D-sub Connectors, Housings & Accessories User Manual

Page 97

Advertising
background image

05

96

D-Sub

D-Sub

1

5

10

50

100 500 1000

30

35

1 11 16 35 32

1

3 12 24 38 30

1 6 11 25 35 38 32

47

470

1000

3900

Min. insertion loss

1)

Capacitance tolerance = ± 20 % (For other capacitor values see pages 05.122 ff).

Measured in 50 Ω system according to MIL-STD-220, no load.

Working voltage:

100 V max. for standard capacitance values – higher working

voltages are available as specific.

Dielectric withstanding voltage: 250 V DC max. – higher dielectric withstanding voltages are

available as specific (see page 05.122)

Inser

tion loss [dB]

Frequency [MHz]

Typical insertion loss for different filters (measured)

Attenuation characteristics for standard capacitance values

Capacitance [pF]

1)

Frequency [MHz]

Attenuation (in dB) vs. frequency [MHz]