D-sub housing range – Northern Connectors Harting D-sub Connectors, Housings & Accessories User Manual

Page 166

Advertising
background image

05

165

D-Sub

Mounting details

Crimp flange termination instruction

1. Strip the cable sheath to the correct length

(approx. 35 to 40 mm, depending on interface

type).

2. Place the crimp ferrule over the cable sheath.

Bend the outer screen backwards over the

cable sheath. Cut screen approx. 2 mm from

the end of the cable sheath.

3. Place the crimp flange over the wires covered

by the remaining foil shield. Push and twist

the crimp flange under the outer screen

and cable sheath until the end of the cable

sheath touches the crimp flange. HARTING

has

developed a special tool for optimised

installation of the shielding over the crimp

flange, part number 61 03 600 0017.

4. Move the crimp ferrule back onto the crimp

flange and crimp the two parts together with

the special service crimp tool part number

61 03 600 0020. For an optimised crimp process

the tool should to be positioned as close as

possible to the crimp flange sholder.

5. Cut off the internal screen foil and push the

crimp flange inside the metal hood.

HARTING offers to test and define the best
crimp flange and ferrule combination for
customer specific cables.

D-Sub Housing range