D-sub, Pcb solder version technical characteristics – Northern Connectors Harting D-sub Connectors, Housings & Accessories User Manual

Page 5

Advertising
background image

05

04

D-Sub

M

F

M

F

M

F

M

F

M

F

D-Sub

PCB solder version

Technical characteristics

Current carrying capacity

The current carrying capacity is limited by maximum temperature

of materials for inserts and contacts including terminals.

The current capacity-curve is valid for continuous, not interrupted

current-loaded contacts of connectors when simultaneous power

on all contacts is given, without exceeding the maximum tempe-

rature.
Control and test procedures according to DIN IEC 60 512.

Contact arrangement

View from termination side

Mating conditions

as per DIN 41 652

M = Male connector

F = Female connector

37 way

50 way

W

or

king current

Ambient temperature

Example: 25 way connector

Turned contacts

Stamped contacts

Number of contacts

9, 15, 25, 37, 50

UL recognized

Working current

see current carrying capacity chart

Turned contacts

7.5 A max.

Stamped contacts

6.5 A max.

Test voltage U

r.m.s.

1 kV

Clearance and creepage

≥ 1.0 mm

Contact resistance

≤ 10 mΩ

Insulation resistance

≥ 10

10

Temperature range

-55

O

C … +125

O

C

The higher temperature limit includes the local ambient and

heating effect of the contacts under load

Terminations

a) Solder pins Ø 0.6 mm for

P.C.B. holes Ø 0.8/1 mm

b) Solder pins, angled 90

O

Ø 0.6 mm for P.C.B. holes

Ø 1 mm

Materials

Mouldings and hoods

Thermoplastic resin, glass-

fibre filled (PBTP),

UL 94-V0

Contacts

Copper alloy

Contact surface

Contact zone

selectively plated according

to performance level

1)

Metal shell

Plated steel

Insertion and withdrawal force

Connector on P.C.B.

Solder, straight with clips

– insertion max. per connector:

60 N

– withdrawal min. per connector:

10 N

Mating force

9 way ≤ 30 N

15 way ≤ 50 N

25 way ≤ 83 N

37 way ≤ 123 N

50 way ≤ 167 N

1)

Performance level 3, 50 mating cycles, no gas test

Performance level 2 as per CECC 75 301-802, 250 mating cycles, 4 days 4 mixed gas test – IEC 60 512

Performance level 1 as per CECC 75 301-802, 500 mating cycles, 10 days 4 mixed gas test – IEC 60 512

9 way

15 way

25 way

Advertising