05
199
D-Sub
9
09 18 009 7005
15
09 18 015 7005
25
09 18 025 7005
37
09 18 037 7005
Important: always store reel vertically
No. of
Identification
contacts
Part No.
Drawing
Dimensions in mm
Flat cable
colour coded
Length per reel
30.48 m (100 feet)
UL AWM-style 2651
Conductor material _________________ Copper tinned
Gauge ___________________________ AWG 28/7 0.09 mm²
Voltage rating ______________________ 300 V
r.m.s.
Current rating at 25 °C ______________ 2.1 A max.
Conductor resistance ________________ 221 mΩ/m
Capacity unbalanced ________________ 42.7 pF/m
Impedance unbalanced ______________ 105 Ω
Inductance unbalanced ______________ 0.68 µH/m
Signal delay _______________________ 4.9 ns/m
Insulation material __________________ PVC
Temperature rating (operating) ________ –20 °C … +105 °C
Temperature rating (static) ____________ –30 °C … +105 °C
Flammability rating _________________ UL: VW 1
Insulation resistance ________________ 100 MΩ/km
Colour code sequence
(in 10 steps)
brown, red, orange,
yellow, green, blue, violet,
grey, white, black
colour
coded
Cables for insulation displacement termination