3. MeAsureMeNT fuNCTIoNs
Level RMS

LEVEL RMS reflects the absolute level of the line input signal.

Fig 3.1 Level RMS Meter Panel

Display

Filter

Measurement

Function

Active

Filter

Frequency
Bargraph

Zoom

Mode

Bargraph

Zoom

Control

Signal

Balance
Level RMS

Result and

Unit

Bargraph with Scaling Information

To enter the LEVEL RMS mode, select LEVEL -> RMS in the

measurement functions submenu.
signal balance: This indicates the deviation from level-match of the

incoming balanced signal between pin 2 and pin 3 in percent (%).

The position of the arrow indicates the following:
• Arrow in center, the input signal is balanced.

• Arrow out of center, linear indication of a balancing problem, e.g.

arrow moves left nearer to the number 2 shows the signal level

on pin 2 is higher than on pin 3.

• Left or right end, the signal balance error is 33% or higher. 33%

equals a difference in the signal level of 6 dB.

• UNBAL, the signal balance symbol changes to UNBAL at the

signal balance error exceeding 90%.

result and unit: Level RMS. The units dBu, dBV, V are selectable.
Bargraph: The bargraph provides an analog display of the RMS level.

The scaling may be controlled automatically or manually.
• Select manual (M) or automatic (A) scaling by the bargraph zoom

mode field.

• Within the manual scaling (M) select the bargraph zoom control,

press enter and the left/right keys to scroll through the