Echnical, Pecification, Technical data general functions – NTi Audio Minilyzer ML1 User Manual

Page 49

Advertising
background image

49

7. TeCHNICAl speCIfICATIoN

Technical Data General Functions

Measurements

- Level-RMS, Level-Relative, Frequency

- THD+N

- vu+PPM

- Polarity Test

- Signal Balance Error

- Sweep, Frequency Sweep, Time Sweep

- 1/3

rd

Octave Spectrum

- Scope, Frequency

- AFILS measurements (with MiniLINK)

frequency

Range

10 Hz to 20 kHz

Resolution

4 digits

Accuracy

< ± 0.1 %

Level

Units

dBu, dBV, V

RMS

Resolution

3 digits (dB-scale) or 4 digits (V-scale)

Accuracy

± 0.5 % @ 1 kHz

Bandwidth

20 Hz to 20 kHz

Flatness

± 0.1 dB

THD+N (Total Harmonic Distortion + Noise)

Meas. Bandwidth 10 Hz to 20 kHz

Resolution

3 digits (dB-scale) or 4 digits (%-scale)

Residual THD+N balanced < -85 dB @ -10 dBu to +20 dBu

unbalanced < -74 dB @ 0 dBu to +14 dBu

vu+PPM (vu-Indicator and Peak Program Meter)

according to IEC 60268 and DIN 45406.

PPM Type I, IIa and Nordic.

Both meters with adjustable reference and

with analog & numerical peak-hold readout.

Polarity Test (with Minirator test signal)

Positive / Negative detection through internal

microphone or XLR/RCA connector. Checks

polarity of tweeters, midrange-speakers,

woofers, sub-woofers and cables. Down to

10 dB S/N ratio of input signal.

Technical Specification