Network Settings
10000000877(02)
15
Setting the IP Address of the MultiSight
Before setting the IP address, make sure that the computer is connected as described in “Electrical Installation” and “Basic Computer 
Settings” (see “Electrical Installation” on page 8 and “Basic Settings for PC and MultiSight” on page 12).
To set the IP address on the MultiSight, proceed as follows in 
the PC software:
1.
Open the MultiSight software.
2.
Click on the “Find” button. After a few seconds, a list of 
sensors in the network appears. If this does not happen, 
repeat the Find process.
3.
Select the desired sensor by clicking on it.
4.
Click on the “Set IP” button and enter the desired IP 
address for the MultiSight (same as the IP address of the 
PC except for the last block, see “Basic Settings for PC and 
MultiSight” on page 12). Click Set to accept.
It is possible to adjust the subnet mask and standard 
gateway using the set IP function. It is recommended to 
not change these settings unless necessary.
5.
Switch the power to MultiSight off and on again, and 
click on Find again to locate the sensor with the newly assigned address.
Note: the period between the sensor re-start and successful Find is approx. 6 sec. If necessary, repeat Find operation.
The MultiSight is now ready for operation at the newly-assigned IP address.
For network operation use only IP addresses which have not already been assigned.
Contact the system administrator to determine which IP 
addresses are allowed on your network for the MultiSight. The IP 
address set for the MultiSight should be marked on the enclosed 
label. After installation, stick the label on the sensor in a clearly 
visible position.
It is not possible to see a MultiSight on a different standard 
gateway than your PC using the sensor finder function.