Rockwell Automation 48MS MultiSight Vision Sensor User Manual
Page 30
 
MultiSight™ User Manual
Start-up
30
10000000877(02)
Parameter
Description
Screen Shot
Logic (continued)
In order to use the grouping functionality, 
Detector Parameter Control Input must be 
set to “Activate 0
31” for ALL active
detectors.
The same Logic is applied to each Group of 
detectors. Example: if the detectors in Group 
A are logically linked with AND, the detectors 
in Group B will be logically linked with AND. 
It is not possible to link Group A with AND 
and Group B with OR.
It is not possible to logically link groups with one another.
The functionality of the left-hand check box is different for 
grouping than for the logical linking previously described. The 
evaluation of a group begins with the detector last selected via the 
Control Input (IN2). (When the sensor is connected to the 
computer for configuration, the radio button currently selected will 
determine which detector the sensor begins the group evaluation 
with.) The sensor evaluates each detector that has a check in the 
left hand box. The next detector that does NOT have a check is the 
last detector in the group. If detectors 1-3 have a check and 4 does 
not, Group A is detectors 1-4. See the screen shot to the right.
The detectors in different groups do not have to have matching 
parameters; however, those within the same group must follow 
the matching parameter guidelines listed above.
IMPORTANT
}
}
Group A
Group B