Rockwell Automation 48MS MultiSight Vision Sensor User Manual
Page 48

MultiSight™ User Manual
Start-up
48
10000000877(02)
Status Line
The Status Line along the bottom right edge of the screen shows the current status of the last action performed.
Field
Description
Result Bar Graph
The degree of conformity of the current pattern with the pattern taught is shown as a bar graph. The status of the
overall inspection is shown as a green (pass) or red (fail) dot. The result is determined by whether the degree of
conformity is within the configured thresholds.
For a standalone detector, the bar graph indicates the degree of conformity.
For logically linked detectors, the bar graph represents the detector with the highest degree of conformity
(measurement value).
The threshold value set in “Detector Parameters” section is shown as a black line.
X/Y Position
Shows the X and Y coordinates of the detected pattern (center of green frame) with reference to the zero point
(upper left-hand corner of the field of view) and a coordinate system of X = 640 and Y = 480 units.
Direction
With “center,” “top,” “top right,” “right,” etc. shows the direction in which the current pattern deviates from the
taught pattern with reference to position. “Center” is displayed (or LED = green/OUT2 = high) as long as the center
of the green frame (green cross) is located inside the blue position frame.
Counters
After every activation of Run mode, the three counters are reset to zero. For the purposes of these counters, an
evaluation cycle of five logically linked detectors (resulting in a single output) is counted as one evaluation.
# Evaluations
Displays the number of evaluation cycles since the last activation of Run mode.
# Good Patterns
Number of evaluation that resulted in OUT1 (pass/fail) output of PASS
# Good Positions
Number of evaluation that resulted in OUT2 (position) output of PASS
Sort result
(Only when logic is set to OR)
Displays which detector had the highest evaluation score
Rotation angle
(Only for contour match)
Displays the angle of the detected contour with reference to the taught contour position. This data is not highly
precise—typical tolerance is ±10°
The Status Line indicates that the software is currently executing
a task. It is best to not attempt additional tasks while the Status
Bar indicates software activity.
E
IMPORTANT