Rockwell Automation 48MS MultiSight Vision Sensor User Manual
Page 31
 
MultiSight™ User Manual
Start-up
10000000877(02)
31
Parameter
Description
Screen Shot
Radio buttons
0…9
(
0…31)
Designates the active detector—by clicking one of the ten radio 
buttons, the corresponding detector is selected and its parameters 
can be configured. The parameters are displayed in the Detector 
Parameters window in the middle of the screen. Only one detector 
can be configured at a time. After restart, the most recently 
selected detector is active. The selected detector evaluates a 
Region of Interest (ROI) which is configured in the Image window. 
If a certain detector is to be tested, select that detector and click 
the Run command button to the left.
Display icon
Checking this box indicates whether the yellow Region of Interest 
(ROI) and red pattern frames should be shown on the Image during 
Run mode even if the detector is not selected with the radio 
button. The Region of Interest (ROI) and pattern frames of the 
detector selected with the radio button are automatically 
displayed during Run mode; other detectors with a check in the 
display icon box are shown but greyed out. This function does not 
affect the performance; it is just included to ease the setup process.
Logical link—The time required for execution increases with the 
number of logically linked active detectors.
The evaluation with logical linking affects both the primary 
inspection pass/fail output OUT1 and the secondary position 
result OUT2.
E