Technical data – Rockwell Automation 48MS MultiSight Vision Sensor User Manual
Page 57

MultiSight™ User Manual
Maintenance
10000000877(02)
57
Technical Data
For use in NFPA79 applications only.
Electrical Data
Certifications
cULus and CE Marked for all applicable directives
Supply Voltage
24 V DC ± 10% (absolute maximum 18…30 V)
Residual Ripple
< 5 Vpp
Current Consumption (no I/O)
200 mA, max.
Inputs IN1/IN2
High 10 V…V+/24V DC (+10%), low 0…3 V
Input Resistance
> 20 kOhm
Trigger Input
rising edge, 10 V…V+/24V DC
Outputs OUT1 - 4
PNP type (sourcing MOSFET)
Output Rating (per output)
200 mA
Output Current (per output)
1.5 A, max., in case of short circuit
Protection Type
Short-circuit (all outputs), inverted polarity, electrical shock (CLASS 2 EN 61140)
Set-up Interfaces
Ethernet (LAN)
Network
Ethernet (configuration only)
EtherNet/IP (data transfer only)
Power On Delay
Approx. 6 seconds
Optical Data
Pixel Number, Technology
640 x 480, CCD
Integrated Lighting
8 LEDs (6 x white, 2 x red)
Integrated Lens, Focal Length
6 or 12 mm, adjustable focus
Lens: (adjustable to infinity)
Min. Operating Distance in mm
Min. Field of View X x Y in mm
Field of View @ 200 mm
6
12
20
20
18 x 14
8 x 6
150 x 100
60 x 40
Depth of focus
approx. ± 5% of operating distance
Mechanical Data
Length x Width x Height
Standard model: 77 x 45 x 45 mm
3
(including connector)
EtherNet/IP model: 81 x 45 x 45 mm
3
(including connector)
Weight
Approx. 160 g
Vibration/Shock
EN 60947-5-2
Operating Temperature—C (F)
0…50° (32…122°) (80% humidity, noncondensing)
Storage Temperature—C (F)
-20…60° (-4…140°) (80% humidity, noncondensing)
Enclosure Type Rating
IP 67
E