Rockwell Automation 48MS MultiSight Vision Sensor User Manual
Page 44
 
MultiSight™ User Manual
Start-up
44
10000000877(02)
Screen Shot
Field name
Description
Display: ROI, Pattern, and 
Position
For currently non-selected detectors whose Display 
Icon check box is selected, the check boxes determine 
whether each respective frame is displayed on the 
image.
Single Image 
(via Trigger)
Allows the user to capture a single image initiated by 
the external (or software) trigger, including trigger 
delay parameter settings. This allows the user to 
capture an image for teaching without stopping the 
production line. This also can be used to identify the 
ideal trigger delay setting.
Redraw (Brightness 
detector type only)
When using the brightness detector type, the image 
will color all of the “dark” (or “light”) pixels blue (or 
other selected color).
Region of Interest (yellow frame with detector #) should always fully 
surround the pattern to be detected. It defines the maximum search 
area in which the pattern will be recognized.
Pattern (red frame)
Defines the pattern or contour to be taught. During the inspection 
process the pattern frame does not have any function other than to 
mark the original location of the taught pattern. The green match 
frame indicates where the pattern was detected.
Position frame (blue)
The Position Control (OUT2) determines whether the detected 
pattern’s center is within this frame.