Rockwell Automation 48MS MultiSight Vision Sensor User Manual
Page 46
 
MultiSight™ User Manual
Start-up
46
10000000877(02)
Position Deviation Check and Frame Type
Position control can be activated when the pattern matching or contour matching detector types are selected. If position control is 
selected, a blue frame is displayed on image screen. The X/Y coordinates for the center of the pattern detected (green cross at the 
center of the green frame) with reference to the top left-hand corner of the image (zero point) is displayed in the result window. The 
increment for X/Y coordinate values while using Detector Type Pattern Matching is 2 pixels so only even coordinate values will occur. 
The center of the detected green pattern area (green cross) is inside the blue frame for correctly positioned parts. In Run mode, this 
will activate the position output OUT2.
The center of the detected pattern (indicated by the green cross 
in the green frame) is within the blue position frame. Position 
output OUT2 would be active.
Pattern
Region of
Interest
Sensor Image
Pattern
Region of
Interest
Sensor Image
Faster
Slower
X