Rockwell Automation Publication 750COM-UM006A-EN-P - January 2013

Chapter 4 Configuring the Profinet Master

Configure the Profinet
Controller

In this example, the SIMATIC NCM Manager simulation tool is used for
describing configuration of the Profinet controller. The following steps are
required for Profinet controller configuration.

1.

Create a new project in Configuration tool.

The project you have just created is displayed on the left pane.

2.

Right-click on the project name (20-750-PNET in this example).

3.

From the Insert New Object menu, choose SIMATIC PC Station.

It will add SIMATIC PC station in your project.

4.

In the left pane, click the + or - sign to navigate folders.

5.

Open the SIMATIC PC Station (1) and double-click the Configuration
symbol.

The ‘HW Config’ window appears.

6.

In slot 1 of the PLC rack, insert a substitute for the PROFINET IO
Controller, IE General.

7.

After the property window appears, enter the IP address and subnet mask.

8.

Right-click IE General and choose Insert Profinet IO System.

Advertising