Slave configuration – Rockwell Automation 20-750-PNET Profinet Single Port Option Module User Manual
Page 42

42
Rockwell Automation Publication 750COM-UM006A-EN-P - January 2013
Chapter 4 Configuring the Profinet Master
3.
Click Yes.
4.
From the Options menu, choose Update Catalog.
This displays a screen showing the newly added device in the treeview.
Slave Configuration
The following steps describe how to add and configure a 20-750-PNET option
module.
1.
In the Hardware Catalog, click the + sign to expand the PROFINET IO
treeview.
2.
Navigate to the folder containing the 20-750-PNET option module (see
previous screen) by opening the Additional Field Devices folder, the
Drives folder, and the Rockwell Automation folder.
3.
Drag the 20-750-PNET icon into the Hardware Configuration window.
This action adds the option module to the Profinet network and
configures it to the controller in a networked relationship.
To configure its Device Name and IP address, right-click the option
module to access its Object Properties dialog box.
4.
In the treeview, click the + sign to expand the device you added.