Programming

6–37

Diagnostics

[Drive Alarm 2]

This parameter displays which alarm
condition is present when bit 6 of [Drive
Status 1] is high. Refer to Chapter 7 for
further alarm information.

A Status description (bit ENUM) is
displayed on line 1 (except Series A
HIMs below version 3.0).

Parameter Number

269

Parameter Type

Read Only

[Latched Alarms 1]

This parameter “stores” the [Drive Alarm
1] indications (see above). Bits will re-
main set (high/1), even if the alarm
condition no longer exists. The bit(s)
must be programmed to zero to release
the stored indications.

A Status description (bit ENUM) is dis-
played on line 1 (except Series A HIMs
below version 3.0).

Parameter Number

205

Parameter Type

Read and Write

[Latched Alarms 2]

This parameter “stores” the [Drive Alarm
2] indications (see above). Bits will re-
main set (high/1), even if the alarm
condition no longer exists. The bit(s)
must be programmed to zero to release
the stored indications.

A Status description (bit ENUM) is
displayed on line 1 (except Series A
HIMs below version 3.0).

Parameter Number

270

Parameter Type

Read and Write

[Input Status]

This parameter displays the on/off status of inputs 1-8 at
TB3 if an optional interface card is installed.

A Status description (bit ENUM) is displayed on line 1 (ex-
cept Series A HIMs below version 3.0).

Parameter Number

55

Parameter Type

Read Only

Motor Therm

Bit 15

Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7

Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0

Bit 14

Unused

Encoder Loss

Load Loss

Enc Cnt Max

Enc Cnt Set

Voltage Check

Bus Charging

Regenerating Current Limit

Regenerating Voltage Limit

Line Loss In Progress

Motor Stalled

Ground Warning

Bit 15

Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0

Mtr Overload

Sync Loss

Bit 14

Hardware Current Limit

Motoring Current Limit

Motor OL Trip

Auto Reset

Phase Loss

Heatsink Temp

Auxiliary Input

4-20 mA Loss

Motor Therm

Bit 15

Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7

Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0

Bit 14

Unused

Encoder Loss

Load Loss

Enc Cnt Max

Enc Cnt Set

Voltage Check

Bit 7 Bit 6

Bit 5 Bit 4 Bit 3

Bit 2 Bit 1 Bit 0

Input 1 - TB3-19
Input 2 - TB3-20
Input 4 - TB3-23
Input 3 - TB3-22
Input 5 - TB3-24
Input 6 - TB3-26
Input 8 - TB3-28
Input 7 - TB3-27

Advertising